This table also provides the minimum cubic inch capacity, as well as the maximum number of conductors (for sizes No. Table 370-16(a) lists the most commonly used metal boxes along with the maximum number of conductors permitted in each. These boxes are calculated by using the number of conductors and their respective sizes. Use Section 370-16 to determine the size box required for No. Unlike junction boxes and conduit bodies, terminal housings supplied with motors are not required to comply with Article 370. Conduit bodies, also referred to as condulets, occur in a variety of types, including: LB, LL, LR, C, etc. Conduit body requirements are located in Section 370-16(c). In no case shall the volume of the box, as calculated in (a), be less than the fill calculation as determined in (b). Two sections refer to these calculations: 370-16(a) Box Volume Calculations, and 370-16(b) Box Fill Calculations. (The phrase "free space" should not be confused with "free conductor" located in Section 300-14.)
#Plaster rings to increase number of conductors free
ģ70-16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodiesīoxes and conduit bodies must be of sufficient size to provide free space for all enclosed conductors. Hazardous (classified) location installations must comply with Articles 500 through 517. Installations in any of the following categories are wet locations: underground, within concrete slabs, in masonry (directly contacting the earth), areas subject to saturation (water and other liquids), and locations unprotected from weather. Dry locations are not normally subject to moisture, except on a temporary basis, such as a building under construction.īoxes, conduit bodies, and fittings installed in wet locations must be listed for that specific use. Partially protected external locations under canopies, marquees, roofed (open) porches, and similar sites are considered damp locations as are some interior locations such as certain basements, barns, and cold-storage warehouses. Damp locations, as defined in Article 100, are locations subject to moderate degrees of moisture. This month's In Focus discusses Installation (Part B).ģ70-15 Damp, Wet, or Hazardous (Classified) Locationsīoxes, conduit bodies, and fittings in damp or wet locations must be placed or equipped so as to prevent the entrance of, or internal accumulation of, moisture. Pull and Junction Boxes for Use on Systems Over 600 Volts, Nominal. Manholes and Other Electric Enclosures Intended for Personnel Entry (new to the 1999 edition), and E. It also covers manholes (including other electric enclosures intended for personnel entry). It covers the installation and use of all boxes (and conduit bodies) used as outlet, junction, or pull boxes, depending on their use.
#Plaster rings to increase number of conductors code
Article 370 contains detailed requirements for box fill and junction box sizing.Īrticle 370 of the National Electrical Code (NEC) covers a variety of provisions pertaining to boxes (outlet, device, pull junction), conduit bodies, and fittings. Of course, not one of these methods is correct. An optional creative method is to back out the junction box screws, insert a blank plate, then tighten the screws, thereby compressing the conductors. Such methods include, but are not limited to: carefully wrapping the conductors around the inside of the box so that no air space remains mashing the conductors down with the thumb, the heel of the hand or even by applying force with the handle of a hammer. Some creative methods have been devised to overpack the conductors into a junction box so that the cover can still be installed.
#Plaster rings to increase number of conductors full
Unfortunately, all too often, electricians remove junction box covers only to find the box crammed full of conductors. To that we add plaster rings single, double, round etc.Contrary to popular electrical opinion, designated rules limit the number of conductors allowed within outlet, device, and junction boxes. This may seem like overkill but when putting in the devices it goes much quicker and there is no question of having the required conductor space.ĭo not forget that 300.14 requires 6" free conductor and on a box of this size 3" outside the box, using 6 AWG on the 50 amp outlet makes getting this much conductor in the box a bit tough.ĩ9% of our work is commercial, the only boxes we use are 4" deep and 4 11/16" deep boxes. Thinkgood both items you show are good for surface installations.ģ0 amp we use a 4"sq Deep box with a two gang "plaster ring" that makes a 4" sq box have the front dimensions of a two gang box but leaves more volume for conductors in the rear.ĥ0 amp we use a 4 11/16" sq Deep box with a two gang "plaster ring" that makes a 4 11/16" sq box have the front dimensions of a two gang box but leaves even more volume for the larger 50 amp conductors in the rear.